Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Yonsei Medical Journal ; : 554-556, 2007.
Article in English | WPRIM | ID: wpr-8725

ABSTRACT

Giant multilocular prostatic cystadenoma (GMPC) is a rare benign tumor involving the prostate gland. Microscopically, it masquerades phyllodes tumor or transitional zone hyperplasia. We report one case of GMPC arising from the prostate central zone (CZ), presenting with long-standing aspermia associated with seminal vesicle fibrous obliteration.


Subject(s)
Humans , Male , Middle Aged , Aspermia/etiology , Cystadenoma/complications , Magnetic Resonance Imaging , Prostate/pathology , Prostatic Neoplasms/complications
2.
Journal of the Korean Society for Therapeutic Radiology ; : 391-396, 1995.
Article in Korean | WPRIM | ID: wpr-139771

ABSTRACT

PURPOSE: The Conformal Radiation Therapy has been widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper, we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for he optimal use of the system in 3-D conformal radiotherapy. MATERIALS AND METHODS: The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from 80% to 20% isodose lines and 90 to 10 were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. RESULTS: Increasing MLC angle (0-75degree) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from 80% to 20% isodose lines, while being the small increase of penumbra width of lead alloy block are agree reasonably with those of MLC within 4.8mm. CONCLUSION: The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.


Subject(s)
Alloys , Film Dosimetry , Pectinidae , Radiotherapy, Conformal
3.
Journal of the Korean Society for Therapeutic Radiology ; : 391-396, 1995.
Article in Korean | WPRIM | ID: wpr-139770

ABSTRACT

PURPOSE: The Conformal Radiation Therapy has been widely used under favour of development of computer technologies. The delivery of a large number of static radiation fields are being necessary for the conformal irradiation. In this paper, we investigate dosimetric characteristics on penumbra regions of a multileaf collimator(MLC), and compare to those of lead alloy block for he optimal use of the system in 3-D conformal radiotherapy. MATERIALS AND METHODS: The measurement of penumbra by MLC or lead alloy block was performed with 6 or 10 MV X-rays. The film was positioned at a dmax depth and 10 cm depth, and its optical density was determined using a scanning videodensitometer. The effective penumbra, the distance from 80% to 20% isodose lines and 90 to 10 were analyzed as a function of the angle between the direction of leaf motion and the edge defined by leaves. RESULTS: Increasing MLC angle (0-75degree) was observed with increasing the penumbra widths and the scalloping effect. There was no definite differences of penumbra width from 80% to 20% isodose lines, while being the small increase of penumbra width of lead alloy block are agree reasonably with those of MLC within 4.8mm. CONCLUSION: The comparative qualitative study of the penumbra between MLC and lead alloy block demonstrate the clinical acceptability and suitability of the multileaf collimator for 3-D conformal radiotherapy.


Subject(s)
Alloys , Film Dosimetry , Pectinidae , Radiotherapy, Conformal
SELECTION OF CITATIONS